| Test Criteria |
Testing Devices |
Equipment Accuracy / Data |
Standards |
| Dimension [mm] |
Accurate Micrometer |
Accuracy Class 1 |
DIN 863 Part 3 Typ D.13 |
| Tensile Strength [N/mm2] |
Tension Testing Machine |
Accuracy Class 05 acc. to EN ISO 7500 |
DIN EN 10002 Part 1 |
| Elongation [%] |
Tension Testing Machine |
Reading Accurancy: ± 1%. Test Length: Lo = 100 mm alternatively: Lo = 254 mm |
DIN EN 10002 Part 1 |
| Coating Thickness [µm] |
Couloscope |
± 10% depending on Conditions |
DIN EN ISO 2177 |
| X-Ray Spectrometer |
DIN EN ISO 3497 |
| Coating Composition [%] |
X-Ray Spectrometer |
± 10% depending on Conditions |
DIN EN ISO 3497 |
| Surface |
Stereo-Microscope |
30 x Magnification |
Internal Specification |
| Solderability % |
Solder-Melting Pot Stereo-Microscope |
Ageing 16 h at 155°C in air
Solder bath 235 ± 5°C
Alloy: Sn/Pb = 60/40 in non activated flux,
Dipping Depth 60 mm |
DIN IEC 68 Ta Part 2-20 Meth. 1, Ageing 3 MIL 202 E, Meth. 208C |
| Coating Adhesion |
Winding Mandrel |
Wire Ø < 1,00 mm :
Mandrel Ø = 1,00 mm,
Wire Ø > 1,00 mm:
Mandrel Ø = Wire Ø
10 tight Windings |
Internal Specification |
| Stereo-Mircroscope |
Microscope: 30 x Magnification |
All testing equipment is subject to periodic monitoring in accordance with our Quality Management System DIN EN ISO 9001:2000.
Stringent quality inspections are performed in each phase of production. These strict production controls ensure consistently
high quality. All measurements are recorded and filed for minimum 15 years.